Hip Distraction System

An advanced limb positioning and distraction system for supine hip arthroscopy procedures with or without a perineal post, the Hip Distraction System (AR-6529S*) includes a patient table and pad, a patient prep platform and pad, two leg spars with traction boots, and a perineal post and pad. A pair of table clamps (based on the mating table rail) are also included. This next-generation hip distraction system features intuitive controls to facilitate preoperative patient setup and intraoperative changes in patient positioning.

The system is engineered out of carbon fiber, aluminum, and other lightweight, unyielding materials that provide maximum rigidity and minimal flex, ensuring distraction forces are maintained and reducing the overall weight for portability from storage to the operating room.

Identical teleTrac Carriages with gross and fine traction controls on the leg spars allow the fluid range of motion necessary during hip arthroscopy procedures. Hip flexion, extension, abduction, and adduction are controlled using the individual operating handles on the end of each spar. The novel traction boots with ratcheting straps provide the most secure and safe attachment for the patient's foot while minimizing heel lift and slip out.

*AR-6529S is sold with two HDS Traction Boot II, AR-6529-23

View More

An advanced limb positioning and distraction system for supine hip arthroscopy procedures with or without a perineal post, the Hip Distraction System (AR-6529S*) includes a patient table and pad, a patient prep platform and pad, two leg spars with traction boots, and a perineal post and pad. A pair of table clamps (based on the mating table rail) are also included. This next-generation hip distraction system features intuitive controls to facilitate preoperative patient setup and intraoperative changes in patient positioning.

The system is engineered out of carbon fiber, aluminum, and other lightweight, unyielding materials that provide maximum rigidity and minimal flex, ensuring distraction forces are maintained and reducing the overall weight for portability from storage to the operating room.

Identical teleTrac Carriages with gross and fine traction controls on the leg spars allow the fluid range of motion necessary during hip arthroscopy procedures. Hip flexion, extension, abduction, and adduction are controlled using the individual operating handles on the end of each spar. The novel traction boots with ratcheting straps provide the most secure and safe attachment for the patient's foot while minimizing heel lift and slip out.

*AR-6529S is sold with two HDS Traction Boot II, AR-6529-23

View More

Educational Resources and Products

Hip Distraction System Traction Boot II Product Demonstration

John Gualdoni
Product Demonstrations | 07:31 | English | 02/07/2022 | VID1-002966-en-US A
Hip Distraction System

Hip Distraction System

Brochures | English | 06/28/2023 | LB1-0369-EN F
Arthrex Hip Distraction System
Arthrex Hip Distraction System
John Gualdoni
Product Demonstrations | 06:54 | English | 07/16/2019 | VID1-000286-en-US A
Videos
(10)
arrow_drop_down
Videos
Documents
(10)
arrow_drop_down
Documents
English
(20)
arrow_drop_down
Languages

Surgical Technique Guides (1)


Agreements (1)

Arthrex HDS Rental Agreement (PRO123)
Arthrex HDS Rental Agreement (PRO123)
English | 01/29/2016 | AG1-100-EN B

Brochures (8)


Case Presentation Videos (1)

Hip Distraction System: Live Case
Hip Distraction System: Live Case
Craig Mauro, MD
11:51 | English | 11/02/2023 | VID1-005613-en-US A

Catalogs (1)


Presentation Videos (3)

Post vs Postless Hip Arthroscopy Debate
Post vs Postless Hip Arthroscopy Debate
John Christoforetti, MD
25:15 | English | 02/01/2023 | VID1-003746-en-US A
Arthrex® Hip Distractor: Tips and Pearls for Optimal Use
Arthrex® Hip Distractor: Tips and Pearls for Optimal Use
John Christoforetti, MD
08:50 | English | 08/12/2015 | VID1-00480-EN A
Hip Arthroscopy: Setup, Femoroacetabular Impingement (FAI), Labral Repair and Reconstruction
Hip Arthroscopy: Setup, Femoroacetabular Impingement (FAI), Labral Repair and Reconstruction
Benjamin G. Domb, MD
13:15 | English | 10/24/2014 | VPT1-00345-EN A

Product Demonstrations (6)

Hip Distraction System Traction Boot II Product Demonstration
Hip Distraction System Traction Boot II Product Demonstration
John Gualdoni
07:31 | English | 02/07/2022 | VID1-002966-en-US A
Arthrex Hip Distraction System
Arthrex Hip Distraction System
John Gualdoni
06:54 | English | 07/16/2019 | VID1-000286-en-US A
HDS Traction Boot
HDS Traction Boot
John Gualdoni
04:41 | English | 05/03/2016 | VID1-00660-EN A
Hip Distraction System
Hip Distraction System
John Gualdoni
02:29 | English | 04/26/2016 | VID1-00678-EN A
Hip Distraction System Product Feature
Hip Distraction System Product Feature
Benjamin G. Domb, MD
05:42 | English | 02/11/2014 | VID1-00070-EN A

Reference Charts (2)


Surgeon Newsletters (1)

Scope This Out - Volume 24, Number 2
Scope This Out - Volume 24, Number 2
English | 09/15/2023 | LN1-000522-en-US A